PHG-50, PHG-80, PHG-100, PHG-150, PHG-200, PHG-300,
PHG-500 |
|
 |
| It
is Vertical Smoke Tube Gas Steam Boiler with two
pass combustible structure-firing room and flue
that keeps the high safety and the perfect combustion
minimizing the ejection of nitrogenous oxide materials. |
|
|
¡Ý There is few fluctuation of steam
loading with the enough big hot-water storage capacity
of boiler.
¡Ý High quality pure steam comes out,even
if not attaching steam separator.
¡Ý Adopting the compulsory mixing
combustion system that can burn up LPG or city public
supplying gas.
¡Ý The very simple design that makes
the easy installing, operating and maintaining at low
cost.
¡Ý Applying the perfect safety appliances
with quality-certificated parts.
¡Ý The most economical one among steam
boilers.
|
 |
|

|
PHG
-30 |
PHG
-50 |
PHG
-80 |
PHG
-100 |
PHG
-150 |
PHG
-200 |
PHG
-300 |
PHG
-500 |
Rated Evaporation
(kg/hr) |
30 |
50 |
80 |
100 |
150 |
200 |
300 |
500 |
Caloric Value
(kcal/hr) |
16,000 |
27,000 |
43,200 |
54,000 |
81,000 |
108,000 |
162,000 |
270,000 |
Highest Working
Pressure (kg/§²) |
3.5 |
3.5 |
3.5/ 7 |
3.5/7 |
3.5/7 |
3.5/7 |
3.5/7 |
3.5/7 |
Maximum Steam
Temperature(¡É) |
138 |
138 |
138/164 |
138/164 |
138/164 |
138/164 |
138/164 |
138/164 |
Heating Surface
Area (§³) |
1.3 |
1.7 |
3.5 |
3.5 |
4.2 |
4.7 |
4.7 |
4.7 |
| Thermal Efficiency (%) |
85.8 |
85.8 |
85.3 |
85.3 |
85.3 |
85.3 |
85.3 |
85.3 |
Gas
Consumption |
Max (kcal/hr) |
22,000 |
33,000 |
70,600 |
70,600 |
99,000 |
160,000 |
199,000 |
295,000 |
| Min (kcal/hr) |
15,000 |
15,000 |
18,000 |
18,000 |
34,500 |
38,700 |
61,000 |
142,000 |
Supply Gas
Pressure (mmH2o) |
200~250 |
200~250 |
200~250 |
200~250 |
200~250 |
200~250 |
200~250 |
200~250 |
Power Consumption
(kw) |
0.514 |
0.514 |
0.514/1.155 |
0.514/1.155 |
0.514/1.155 |
0.829/1.35 |
0.829/1.35 |
0.850/1.55 |
| Gas Mixing System |
External mixing |
External mixing |
External mixing |
External mixing |
External mixing |
External mixing |
External mixing |
External mixing |
| Control System |
ON/OFF (FA) |
ON/OFF (FA) |
ON/OFF (FA) |
ON/OFF (FA) |
ON/OFF (FA) |
ON/OFF (FA) |
ON/OFF (FA) |
ON/OFF (FA) |
| Sources of Electricity |
220V/60Hz
,50Hz |
220V/60Hz
,50Hz |
220V/60Hz
,50Hz |
220V/60Hz
,50Hz |
220V/60Hz
,50Hz |
220V/60Hz
,50Hz |
220V/60Hz
,50Hz |
220V/60Hz
,50Hz |
Power Source
of Control Panel |
1P220V/60
,50Hz |
1P220V/60
,50Hz |
1P220V/60
,50Hz |
1P220V/60
,50Hz |
1P220V/60
,50Hz |
1P220V/60
,50Hz |
1P220V/60
,50Hz |
1P220V/60
,50Hz |
Power Source
of Feed Water Pump
(3.5kg/§²) |
1P220V/60
,50Hz |
1P220V/60
,50Hz |
1P220V/60
,50Hz |
1P220V/60
,50Hz |
1P220V/60
,50Hz |
1P220V/60
,50Hz |
1P220V/60
,50Hz |
1P220V/60
,50Hz |
Power Source
of Feed Water Pump
(7kg/§²) |
None |
None |
3P220, 380,415V |
3P220, 380,415V |
3P220, 380,415V |
3P220, 380,415V |
3P220, 380,415V |
3P220, 380,415V |
| Steam Outlet v/v(A) |
15 |
15 |
20 |
20 |
20 |
32 |
32 |
40 |
| Weight (kg) |
125 |
145 |
290 |
310 |
530 |
720 |
860 |
1,300 |
| Flue Spigot(§®) |
100 |
100 |
150 |
150 |
150 |
250 |
250 |
250 |
| Fuel |
LNG/LPG |
LNG/LPG |
LNG/LPG |
LNG/LPG |
LNG/LPG |
LNG/LPG |
LNG/LPG |
LNG/LPG |
| Width (§®) |
600 |
660 |
860 |
860 |
1,020 |
1,140 |
1,210 |
1,460 |
| Depth (§®) |
790 |
840 |
960 |
960 |
1,410 |
1,530 |
1,660 |
1,850 |
| Height (§®) |
1,420 |
1,570 |
1,560 |
1,560 |
1,600 |
1,800 |
1,900 |
2,240 |
| ¢Ã Specifications are subject to change without notice due to our continuious improvement. |
|
|
 |
|